ID Name Setup 1 Unit (Notes)
009 Display line 2 Output energy [kWh]
010 Display line 1.1 Dc link voltage [V]
011 Display line 1.2 Reference [%]
012 Display line 1.3 Torque [%]
014 Local stop Disable
102 Motor power 15.00 kW
103 Motor voltage 415 V
105 Motor current 28.00 A
106 Motor nom. speed 1450 RPM
108 Stator resist 0.2722 Ohm
109 Stator react. 20.47 Ohm
113 Lo spd load comp 150 % (For hill starts)
114 Hi spd load comp 100 %
115 Slip compensat. -300 % (Gives better throttle response at high speed)
119 High start torq. 0.5 s
128 Mot.therm protec Etr warning1
129 Motor extern fan Yes
200 Out freq rng/rot 132 hz both direct.
202 Out freq hi lim 132.0 Hz
205 Max. reference 132.000
206 Ramp type S2
207 Ramp up time 1 6.00 s (Economy)
208 Ramp down time 1 1.00 s
209 Ramp up time 2 2.00 s (Power)
210 Ramp down time 2 1.00 s
221 Torq limit motor 348.5 %
222 Torq limit gener 60.0 %
224 Warn. current hi 97.6 A
227 Warn. feedb. low -4,200.000
228 Warn. feedb high 4,200.000
300 Digital input 16 No operation
301 Digital input 17 No operation
302 Digital input 18 Latched start
305 Digital input 29 Ramp 2
306 Digital input 32 No operation
307 Digital input 33 Encoder fb, input a
314 Ai [mA] 60 funct No operation
319 Ao 42 function Fb min-max =0-32000p (Speedo)
320 Ao 42 puls scale 66 Hz
321 Ao 45 function 0-tlim = 0-32000p (Tacho)
322 Ao 45 puls scale 99 Hz
323 Relay 1-3 funct. No operation
326 Relay 4-5 funct. No operation
329 Encoder pulses 40 (Inductive pickup gear)
405 Reset mode Automatic x 2
410 Inv.fault delay 35 s
411 Switch frequency 3.0 kHz
415 Max. feedback 4,500.000
416 Ref/feedb. unit Rpm
417 Speed prop gain 0.015
445 Flying start Enable
446 Switch pattern 60° avm
457 Mains imbalance Warning